The laboratory holds two accreditation certificates from the Saudi Accreditation Center, both to ISO/IEC 17025:2017 — one for calibration, one for testing. They are reproduced below from the documents themselves, together with the scope annex that defines exactly what they cover, and what they do not.

CalibrationISO/IEC 17025:2017

Certificate

N-C-00592

Saudi Accreditation Center

Issued

30-07-2026

Valid to

29-07-2029

Accredited fields

MassMechanicalTemperatureChemical

Published from the certificate document

TestingISO/IEC 17025:2017

Certificate

N-T-00607

Saudi Accreditation Center

Valid to

12-10-2027

Accredited fields

Food and agricultural microbiology

Published from the certificate document

ANNEX

The scope, line by line

Accreditation applies line by line, never to a laboratory as a whole. The ledger reproduces the scope annex of certificate N-C-00592 in full — each parameter with its accredited range and CMC, grouped by field exactly as the annex prints them — and the accompanying figure draws those ranges to scale.

Mass measurements

04 LINES
ParameterRangeCMC ± uncertainty
Mass measurements, F1 and below class weights1 g, 2 g, 5 g, 10 g, 20 g, 50 g, 100 g, 200 g0.000010 g to 0.00010 g
Weighing balances1 mg to 120 kg0.060 mg to 0.080 g
Micropipette, gravimetric method200 µL to 5000 µL8.20 µL to 29.10 µL
Glassware: cylinders, flasks, beakers, burettes, pipettes, pycnometers1 mL to 100 mL0.0082 mL to 1.79 mL

Mechanical measurements

01 LINES
ParameterRangeCMC ± uncertainty
Pneumatic pressure gauges0 kg/cm² to 35 kg/cm²0.004 kg/cm² to 0.288 kg/cm²

Temperature measurements

05 LINES
ParameterRangeCMC ± uncertainty
Temperature and humidity5 °C to 60 °C; 3 % to 95 % RH0.71 °C; 0.71 % to 1.55 % RH
Infrared thermometer, black body sourceAmbient to 500 °C3.9 °C to 6.0 °C
Thermometers: liquid-in-glass, dial and digital−40 °C to 1200 °C0.4 °C to 3.0 °C
Thermocouples with indicator (Type K, S and N), RTD with indicator−40 °C to 1200 °C0.4 °C to 3.0 °C
Cooling and heat generating sources: liquid baths, dry blocks, temperature calibrators, furnaces−40 °C to 1200 °C0.4 °C to 3.0 °C

Chemical measurements

02 LINES
ParameterRangeCMC ± uncertainty
pH meter4, 7 and 10 pH0.12 pH
Conductivity meter1413 µS/cm7.2 µS/cm

Transcribed from the scope annex of certificate N-C-00592, pages 2 to 4. Twelve lines, all active. Where the annex prints discrete values the list is reproduced; where it prints a span, the span is reproduced.

Figure · Accredited measurement ranges
Accredited ranges from SAAC certificate N-C-00592, twelve active lines. Logarithmic axis — the scope spans eight orders of magnitude.

BOUNDARY

What is not covered

A scope is defined as much by what it excludes as by what it contains. The statements below carry the same weight as the certificates above: work outside the scope is available, and it is said to be outside the scope before it is commissioned.

Not accredited

Dimensional calibration

Dimensional calibration is offered as non-accredited in-house work. It has no line in the scope annex, and no certificate from this discipline carries or implies an accreditation mark.

Not accredited

Electrical calibration

Electrical calibration is offered as non-accredited in-house work. It has no line in the scope annex, and no certificate from this discipline carries or implies an accreditation mark.

Where testing stops

Testing stops at food and agricultural microbiology

Certificate N-T-00607 covers food and agricultural microbiological testing, and nothing else. No other testing field is accredited, and no page on this site implies otherwise.

VERIFICATION

How to verify these credentials

This page is the laboratory’s account of its own accreditation. The authoritative record is the public register of the issuer, and checking it takes three steps.

Register query

Issuer
Saudi Accreditation Center
Record
The SAAC public register
Calibration
N-C-00592
Testing
N-T-00607
  1. Take the certificate number

    Calibration is held under N-C-00592 and testing under N-T-00607. A certificate number is a claim until it has been checked against the body that issued it.

  2. Consult the SAAC public register

    The Saudi Accreditation Center maintains the public register of accredited laboratories in Saudi Arabia. An entry there under these numbers is the confirmation that matters — this website is not the source of record.

  3. Read the scope, not the badge

    Confirm that the line covering the instrument or sample in question appears in the annex above. Accreditation applies to those lines, and to nothing beyond them.

CYCLE

Accreditation runs on a cycle

An accreditation certificate is not a permanent award. It is issued for a period, kept under surveillance within that period, and renewed before it lapses — which is why the validity dates above are printed as prominently as the numbers.

Figure · The accreditation cycle
Assessed, issued, kept under surveillance, renewed. The only dates drawn are the issue and expiry printed on the certificates themselves — the surveillance calendar between them belongs to the issuer.

Requests are read at the bench.

Send the sample question or the instrument list. It is read by a bench professional, not routed through a ticket queue. Confirmed phone, mailbox and address publish here at launch.